Products Contact us
 
   
 
 

Wireless Fingerprint Access Control

 

DG-190 DG-190

Specifications :

FP scanning mode

CMOS optical sensor
Capacity
300 fingerprints (100 users )
Match mode
1:N 1:10 1:1
Scanning time
<1 second
Recognition
< 0.2 second /a fingerprint
FAR
<0.004%
FRR
<3%
Translation tolerance
+-3mm
Rotation tolerance
<+-15
Power supply
9V constant-voltage power supply or 6 pieces of No.5AA alkaline cells
Contour size (mm)
222x150x83
Net weight
1200g
Controllable amount of door locks
8 locks
Distance of wireless unlocking
0.5~15M (opening distance)
 

 

Environment :

Operating Temperature

0 - 45º C
Relative Humidity
10% - 85%
         
         
 
 

BiosmartAcess Control System

Fingerprint Access Control System.
The basic fingerprint lock system is comprised of Fingerprint management unit (controller) , Lock-body control box, and Electric lock-body. DG-190 is suitable for

  • House

  • Office

  • villa

  • laboratory

  • information center

  • warehouse

  • star hotel

and other place

 

 

The Door Guard basic system

The main characteristic

Communication mode
The wireless or wiree communication mode can be adopted between the fingerprint management unit and the lock-body control box. The wireless communication mode is convenient for installation and use; at the same time it also increases the door lock safety.

 

  • Two Level User management
    There are two management levels in the system. Administrator can set up functions for the users and he can be restricted for opening the door. User fingerprint can only open doors but they can not enter into main menu to set up functions. The different authority can carry out different operations. Each door lock has two levels management modes, which are independent, each other.

  • Multi-person unlocking mode
    This mode is used at some special places, where two or more persons should get together to get an access into the place. This mode is a special setup to increase security. A person can use his two fingers to increase the system security as well. 

  • The masses control mode
    One fingerprint control unit can control many door locks (1 to 8 door locks). Each door lock has different management modes independent each other. By this way, user can manage the system concentrated and the cost of the system can be reduced.

  • Grouping match and ID number match
    When the stored fingerprint is over a certain amount (ten persons or 30 fingerprints) in the system, the grouping match and ID number match will be automatically adopted to increase the match speed and the system security. 

  • Real-time clock
    It makes the system to be used at more wide places to carry out smart management for door access control and unlocking records.

  • LCD
    This model has two line LCD  which is convenient for the operation and management.

serial of electric lock






  • Undercurrent prompt:
    The system prompts “Undercurrent, change battery!” when the battery is at low voltage. Under this situation, you should change battery in time. After the battery is changed, the original stored fingerprints, passwords, records remain unchanged.  You can use the Password option to unlock the door under extreme low voltage situation where the fingerprint ID could not be matched.

  • Password unlocking
    When you could not normally use your fingerprint because of its bad quality or damage, you can use 5-10 digit password to unlock the door.

  • saving electricity mode
    When environment light is enough, you can turn off the LCD backlight to save battery energy

  • Door access control management
    To increase the system security, the workdays (Monday to Friday), rest days (Saturday to Sunday) and valid time period of each day for persons to get into, can be incorporated into the system.. 
    One's valid time period can be setup (like the start time of the day, month, year. and the end time of the day, month, year) to allow the person unlock the door in his valid time period only.
     

  • Unlocking record
    The system can completely record the door opener's name, unlocking time and the unlocked door number (under the masses control mode).

  • Match levels
    The match level should be set up according to different places or situations. The higher the level is, the higher the security is (the default security level is 3).

  • Larger  capacity ( 100 users, 300 fingerprints).
    This model system fingerprints are distributed into three administrators, ninety seven common users. Password storage  is just the same as fingerprint storage. Each password or fingerprint occupies one fingerprint storage space.

  • Networking
    Computer can extract opening door records from the system at real-time or at any time.
    Computer can monitor information of each terminal stored  fingerprints at any terminal and collect information of authority, valid period of time, door number and every information stored in the terminal. Computer can also  update the  information of  any terminal.
    Fingerprint or password can be upwardly transmitted and be matched for (check) attendance.
    In an emergency, computer can control remote opening a door.
    The system has Off-line (check) attendance function for night watchman.
    The system has computer alert function for abnormal condition.
    Computer can adjust the controller clock to ensure time accuracy for opening door record and door access control



    Application System

       >>1.Standard off-line door access control 
      
    >>2.Off-line ganged door access control 
      
    >>3.Off-line group-controlled door access control
      
    >>4.Standard networking door access control
      
    >>5.Standard networking attendance recorder
      
    >>6.Standard networking door access control and attendance recorder
      
    >>7.Networking group-controlled door access control and attendance recorder


       >>1.Standard off-line door access control
    This model terminal+lockset controll box+ locksets

The basic applicable type, fingerprint recognition terminal scans and matches fingerprint. After fingerprint identification test is passed, the system informs lockset control box, which controls unlocking of locksets including
electric lock, negative pole lock, electric mortise lock, electro-magnetic lock and so on.


   >>2.Off-line ganged door access control
This model terminal+ Lockset control box+locksets+ telephone speech sound alarm.

This model terminal can save coerced fingerprints. When a user has to unlock with coerced fingerprint, unrecognized times are over the preset upper limit or lockset is prized, lockset control box will send out a signal to telephone alarm, which will make a speech alert phone to the preset telephone subscriber, such as the host or public security department. 

   >>3.Off-line group-controlled door access control
This model terminal + (lockset control box + locksets) x N

This model terminal can save many fingerprints and control locksets respectively.

   >>4.Standard networking door access control
Computer + networking DG190 management software + (standard off-line door access control system) x N 


   >>5.Standard networking attendance recorder
Computer + AT100 fingerprint attendance management software + DG190 terminal x N


   >>6.Standard networking door access control and attendance recorder


   >>7.Networking group-controlled door access control and attendance recorder
Computer + AT100 fingerprint attendance management software + networking DG 190 management software + (off-line group-controlled door access control system) x N


         

 
M-210 M-220 M-230 M-240
[ Fingerprint ID Door Lock ] [ Fingerprint ID Safe Box ] [ Bio Character Products ] [ Wireless Fingerprint Access Control ] [ Remote Control ]